UFD Detonation Proof Flame Arrester
TOPSAFE

UFD Detonation Proof Flame Arrester

Detonation proof in-line flame arrester, rated to stop an ignited vapour mixture travelling at subsonic or supersonic velocity and to absorb the resulting high shock pressure. The step up from the KSFL, which handles subsonic deflagration only.

Type
Detonation and deflagration proof, in-line
Design codes
API 2000; BS 7244; EN 12874; USCG; IMO MSC/Circ.677
Gas group
Standard flame cell suitable for NEC group D or IEC IIA gases; cells for other gas groups available as additional extras
Flame velocity
Designed to stop an ignited flammable vapour mixture travelling at subsonic or supersonic vapour velocities
Shock pressure
Capable of absorbing high shock pressure
Endurance burn
Designed to protect against continuous burning against the 316LSS flame cell for a specific period
Flow
Bi-directional
Installation
Vertical or horizontal
Housing materials
Carbon steel (epoxy coated), 304SS or 316SS housing with 316LSS flame cells
Connection
Standard flanges ANSI 150lb; other connections available upon request